This is an actual inspection report format — property details changed, findings representative. What you receive looks exactly like this.

Parakh

Inspection Report

Standard Plan · 75-point inspection

Report #BT-2024-0847

Inspected: 14 Nov 2024

Delivered: 14 Nov 2024, 11:42 PM

Property

2BHK, 3rd floor

Location

Sector 49, Gurgaon

Built-up area

~1,100 sqft

Inspector

Ramesh P.

Executive Summary

2

High Priority

2

Medium Priority

1

Low / Info

Overall assessment: Property has 2 high-priority issues that should be resolved before signing or factored into negotiation. Structural condition is adequate. Recommend conditional move-in only after addressing high-priority electrical and seepage findings.

Detailed Findings

High

Master Bedroom

Active seepage behind wardrobe, NW wall

Moisture meter reading: 78% (threshold: 25%). Hidden behind freshly painted surface. Likely source: external waterproofing failure or terrace drainage issue above.

Recommendation:Pre-move-in repair essential. Negotiate reduction or written commitment to fix within 30 days.

📷 Moisture meter reading 78% on bedroom wall, annotated photo

High

Kitchen

Faulty earthing — socket near sink

Socket tester confirmed incorrect earthing on kitchen socket adjacent to sink. Water proximity makes this a direct shock hazard.

Recommendation:Request immediate electrician fix before signing. Non-negotiable safety item.

📷 Socket tester showing earthing fault, kitchen

Medium

Bathroom 2

Drainage slow — potential partial blockage

Drain cleared in 4.2 minutes (standard: <2 min). Likely partial blockage in the P-trap. Functional but will worsen.

Recommendation:Request plumber visit before move-in. Low cost to fix (₹500-800).

📷 Drain timer documentation, bathroom 2

Medium

Living Room

Hairline cracks — 3 locations, E wall

Three hairline cracks noted, 20-35cm length each. Current assessment: cosmetic/settling, not structural. Monitor if worsening.

Recommendation:Document with photos. Not a deal-breaker but should be noted in the lease agreement.

📷 Crack documentation, living room east wall

Low

All Rooms

General electrical — 9/11 sockets pass

9 of 11 sockets tested pass earthing and polarity check. 2 sockets (bedroom 2, main hall) excluded from finding above.

Recommendation:No action needed for the 9 passing sockets.

📷 Socket testing log, all rooms

Negotiation Talking Points

Use these when talking to the landlord. They're framed as reasonable asks, not demands.

Must-have

Active seepage, master bedroom

Repair before move-in OR ₹5,000-8,000 deposit reduction + written timeline

Must-have

Faulty kitchen socket earthing

Electrician certification before move-in. Non-negotiable for safety.

Recommended

Slow bathroom 2 drainage

Plumber visit before move-in. ₹500-800 cost to them, major inconvenience to you.

Recommended

Hairline cracks — document in lease

Add clause: cracks noted at move-in, not tenant liability at move-out.

Reviewed by: Senior Inspector, Suresh K.